Tests/Procedures: 1. Based upon stored fault codes for secondary air system, there is little or no flow of secondary air into engine. Typical causes for this issue are failed secondary air pumps and/or secondary air check valves. Secondary air pump should operate under normal circumstances when vehicle is first started to perform system test. Pump will normally be heard running when standing in front right corner of vehicle. 2. The secondary air pump is located in the right front of engine compartment. A secondary air pump relay located in the glove box is controlled by the engine control module and sends power to the secondary air pump. 3. Air pump can be disconnected and supplied with power and ground at pump to verify operation is possible.