Filed Under (Audi) by admin on 15-09-2009

Check the following wire connection for open circuit according to wiring diagram:Relay carrier in E-box, plenum chamber, position 3Terminal Harness connector atignition coils Terminal 8 1 Specified value: Wire resistance max 1.5 – If necessary, repair wire connection. Audi A4 Sedan 2002-2004, Audi A4 Avant 2002-2004, Audi A4 Cabriolet 2003-2004 – 1.8 Liter 4-Cyl. 5V Turbo Generic Scan Tool, Engi…Page 5 24-158 If no malfunctions are found in wires: – Check voltage supply of Motronic Engine Control Module (ECM) voltage supply relay – J271 – Page 24-158 . – Check activation of Motronic Engine Control
Module (ECM) voltage supply relay – J271 – Page 24-159 . Checking voltage supply If specified value is not obtained:
- Connect multimeter for voltage measurement as follows. Relay carrier in E-box, plenum chamber, position 3
Terminal

Related entry:

1998 audi plenum tray, relearn proceedule on holden astra ecm installed, fix heated seats in a 2004 envoy, 2004 Optra Repair Manual, 2004 optra rad, owners manuel for 2004 audi a4 1 8, 2002 audi a4 diagnostic climate panel, power steering rack and pinion audi a6 2004 3 liter 4B1-422-052 D, Suzuki XL7 Repair Manual 2002 free with no registration, audi A4 avant 2004 model engine wiring diagram,

2000 Audi A4 Engine has extended crank time after sitting for more than a few hours

0

Filed Under (Audi) by admin on 11-06-2010

download
2000 Audi A4 Quattro 2.8L, Vin H, Eng 2000 Audi A6 Quattro 2.8L, Vin H, Eng Cfg V6, Eng Des ATQ, USA/Canada Cfg V6, Eng Des ATQ Potential Causes: Engine Mechanical — Mechanical fault causing lack of closed loop operation (vacuum leak/low fuel pressure). Oxygen (O2) Sensors Defective Thermostat Tech Tips: If engine is running too cold, the oxygen sensors will not be enabled by powertrain control module and the allowed time to run the monitor for oxygen sensors will expire, setting the DTC with no other specific fault with the oxygen sensor. 3. If there is no voltage then test for voltage between terminal 1 of the vehicle harness and vehicle ground. Specification with the vehicle running is battery voltage. If voltage specified is not obtained then check the wiring from terminal 1 to the fuel pump relay using available wiring diagrams. 4. If voltage is as specified then test voltage between the vehicle harness terminal 2 and battery positive. Specification with the vehicle running is battery voltage. If specified voltage is not obtained then inspect the wiring between the O2 harness terminal 2 and Engine Control Module (ECM) terminal 5 for open circuit.

Related entry:

2000 Audi A6 Manual PDF,

Audi A6 Electrical Wiring Manual

0

Filed Under (Audi) by admin on 03-10-2009

Audi A6 Electrical Wiring Manual: 1998-2000 covers Audi A6 models built on the “C5″ platform through model year 2000. This manual has been prepared us- ing factory wiring diagrams, electrical component location information and scantool diagnostics. Whether you’re a professional service technician or a do-it-your- self Audi owner this manual will be indispensable as a source of the same detailed electrical system information available at an authorized Audi dealer

A6 Sedan 1998, 1999, 2000 A6 Avant 1999, 2000 allroad quattro 2000

download

Related entry:

2002 audi a6 headlight connector plug how to dissconnect, kia cd5 electrical diagram,

Audi Manual Service Reset – Audi A4 and A6 (1995 – 1999)

0

Filed Under (Audi) by admin on 25-05-2010

download
1. With the ignition switch in the OFF position, press and hold button A whilst turning the key to the ON position. 2. The message “Service OIL” will appear. If the message does not display, repeat step 1. 3. Pull out the button B until the message is extinguished. 4. The display should now show “Service —”, indicating that the SRI has been reset.
Audi Manual Service Reset – Audi A4 and A6 (1995 – 1999)

Related entry:

07 audi q7 epc light on, 199 audi a6 throttle position sensor relearn, 1998 audi a4 2 8 throttle relearn, audi how long ecu reprogram after repair, resetting 2010 audi a4 alarm, throttle body relarn 99 audi a6,

Audi V8, Audi A8 GEAR BOX CONTROL UNIT

0

Filed Under (Audi) by admin on 24-05-2010

download
GEAR BOX CONTROL UNIT MODELS AFFECTED: Audi V8 from ’91 & A8 from ’94 FAULT: 018 gearbox the ATF cooler pipe connection leaks at gearbox. CAUSE: The ATF cooler pipe vibrates this causes the pipe adapter at the gear box to leak. SOLUTION: Do not replace control unit. It is possible to code with VAG 1551 with a workshop
code smaller than 655 36.